Compare home Level 2 chargers
Every charger's numbers read from its maker's own page, dated and linked, with the circuit each one needs worked out.
19 chargers15 makersRead No prices, no paid placement
Pick the circuit you have, or plan to have. The table shows what each charger would draw on it, and dims the ones that cannot be set that low.
Your circuit
Your car's port
19 chargers.
| Charger | Top current | Breaker it needs | Install | Port | Cable | Enclosure | Wi-Fi | Safety listing | ENERGY STAR | Warranty |
|---|---|---|---|---|---|---|---|---|---|---|
| Lucid Connected Home Charging StationLucidMaker's page, read 2026-11-16The full 80 A needs a 100 A breaker, and few cars accept that much on AC. | 80 A, 19.2 kWabout 56.3 miles an hourSettings: 6, 12, 16, 20, 24, 28, 32, 36, 40, 48, 56, 64, 72, 80 A | 100 A at top current | Hardwired | J1772, NACS | 24 ft | NEMA 3R | Yes | UL 1998, UL 2231, UL 2594 | not stated | 4 years |
| Autel MaxiCharger AC Elite Home 50AAutelMaker's page, read 2026-11-16The maker says the full 50 A needs a 70 A circuit. The 40 A plug-in versions are separate models, and its own store page gives the enclosure as IP65 / NEMA 4X. | 50 A, 12 kWabout 35.2 miles an hourSettings: 16 to 50 A | 70 A at top current | Hardwired, NEMA 14-50 plug, NEMA 6-50 plugPlug: up to 40 A | J1772 | 25 ft | NEMA 4 | Yes | CSA certified | Yes | 3 years |
| ChargePoint Home FlexChargePointMaker's page, read 2026-11-16The maker limits the plug-in models to 32 or 40 A, and says a plug-in install outdoors needs an outdoor-rated GFCI breaker upstream. | 50 A, 12 kWabout 35.2 miles an hourSettings: 16, 24, 32, 40, 48, 50 A | 70 A at top current | Hardwired, NEMA 14-50 plug, NEMA 6-50 plugPlug: up to 40 A | J1772, NACS | 23 ft | Type 3R per UL 50E | Yes | UL and cUL listed | Yes | 3 years |
| FLO Home X6FLOMaker's page, read 2026-11-16Ships set to 48 A hardwired and 40 A on the NEMA 14-50 version. | 50 A, 12 kWabout 35.2 miles an hourSettings: 6 to 50 A | 70 A at top current | Hardwired, NEMA 14-50 plugPlug: up to 40 A | J1772, NACS | 25 ft | Type 4X | Yes | UL listed to UL 2594 | Yes | 5 years |
| Emporia Classic Level 2 EV ChargerEmporiaMaker's page, read 2026-11-16Set in one-amp steps up to the configured maximum; the maker does not state the lowest setting. 48 A is hardwired only. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: up to 48, in 1 A steps A | 60 A at top current | Hardwired, NEMA 14-50 plugPlug: up to 40 A | J1772, NACS | 25 ft | NEMA Type 4 | Yes | UL certified | Yes | 3 years |
| Emporia Pro Level 2 EV ChargerEmporiaMaker's page, read 2026-11-16Comes with an energy monitor and load management the maker says is meant to avoid a panel upgrade. 48 A is hardwired only. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: up to 48, in 1 A steps A | 60 A at top current | Hardwired, NEMA 14-50 plugPlug: up to 40 A | J1772, NACS | 25 ft | NEMA Type 4 | Yes | UL certified | Yes | 3 years |
| Enphase IQ EV Charger 2EnphaseMaker's page, read 2026-11-16This row is the Wi-Fi model the maker sells for homes. The same line has 64 A and 80 A cellular models. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 6 to 48 A | 60 A at top current | Hardwired, NEMA 14-50 plugPlug: up to 40 A | J1772, NACS | 25 ft | NEMA 4 | Yes | UL certified | Yes | 5 years |
| EVIQO Level 2 EV Charger, 48A, HardwiredEVIQOMaker's page, read 2026-11-16The maker's own pages disagree on whether a 50 A setting exists; this row uses 48 A, which they agree on. J1772 and NACS are separate products. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 16, 32, 40, 48 A | 60 A at top current | Hardwired | J1772, NACS | 25 ft | IP66 / NEMA-4 | Yes | ETL | Yes | 3 years |
| Ford Connected Charge StationFordMaker's page, read 2026-11-16The page says it meets the ENERGY STAR program requirements, which is not the same words as certified. Ford's install manual gives the enclosure as NEMA Type 3S. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 12, 16, 20, 24, 32, 40, 48 A | 60 A at top current | Hardwired | J1772 | 20 ft | IP-65 | Yes | Conforms to ANSI/UL 2594, as the maker words it | not stated | 3 years |
| Lectron NEXUS Level 2, 48 Amp, HardwiredLectronMaker's page, read 2026-11-16The 48 A version must be hardwired; the plug-in and NACS versions are separate listings. App control is only on the separate NEXUS Pro. | 48 A, 11.52 kWabout 33.8 miles an hour | 60 A at top current | Hardwired, NEMA 14-50 plugPlug: up to 40 A | J1772, NACS | 23 ft | IP66 | No | ETL listed (UL 2594, UL 2231, UL 2251) | Yes | 3 years |
| Leviton EV48W, 48 Amp with Wi-FiLevitonMaker's page, read 2026-11-16The maker says it is hardwired only, needs a 60 A breaker, and charges a Tesla only with an adapter. | 48 A, 11.52 kWabout 33.8 miles an hour | 60 A at top current | Hardwired | J1772 | 18 ft | NEMA Type 3R | Yes | cETLus | not stated | 2 years |
| Rivian Wall Charger, NACSRivianMaker's page, read 2026-11-16The maker says it must be hardwired and is not compatible with a J1772 port without a separate adapter. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 6, 12, 16, 20, 24, 32, 40, 48 A | 60 A at top current | Hardwired | NACS | 24 ft | NEMA Type 3R | Yes | UL 1998, UL 2231, UL 2594 | Yes | 4 years |
| Schneider ChargeSchneider ElectricMaker's page, read 2026-11-16The datasheet says the current is adjustable by the installer but lists no settings. J1772 and NACS are separate part numbers. | 48 A, 11.52 kWabout 33.8 miles an hour | 60 A at top current | Hardwired | J1772, NACS | 25 ft | Type 4 | Yes | UL 2594, UL 2231-1, UL 2231-2 | Yes | 3 years |
| Tesla Universal Wall ConnectorTeslaMaker's page, read 2026-11-16J1772 is through an adapter that docks in the side of the unit. A 13.1 ft cable version also exists. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 12, 16, 24, 32, 40, 48 A | 60 A at top current | Hardwired | NACS, J1772 | 24 ft | Type 3R | Yes | cULus on the datasheet; ETL/cETL in the current manual | Yes | 4 years |
| Tesla Wall Connector (Gen 3)TeslaMaker's page, read 2026-11-16The manual says no adapters may be used with it, and the warranty is 12 months in commercial use. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 12, 16, 24, 32, 40, 48 A | 60 A at top current | Hardwired | not stated | 24 ft | Type 3R | Yes | cULus | not stated | 4 years |
| Wallbox Pulsar Plus 48AWallboxMaker's page, read 2026-11-16The 48 A model is hardwired only; the plug is offered on the 40 A model. | 48 A, 11.52 kWabout 33.8 miles an hourSettings: 16 to 48 A | 60 A at top current | Hardwired | J1772, NACS | 25 ft | NEMA Type 4 | Yes | UL certification (NRTL), UL 2594 | Yes | 3 years |
| Grizzl-E Classic 40AUnited Chargers (Grizzl-E)Maker's page, read 2026-11-16The current limit is set with switches inside the unit. A 5 year warranty is offered as an option. | 40 A, 9.6 kWabout 28.2 miles an hourSettings: 16, 24, 32, 40 A | 50 A at top current | NEMA 14-50 plug, NEMA 6-50 plug | J1772 | 25 ft | UL Type 4 | No | UL listed (E510712) | Yes | 3 years |
| Grizzl-E Classic Connect 40AUnited Chargers (Grizzl-E)Maker's page, read 2026-11-16Sold with a NEMA 14-50 plug; the maker's FAQ says it can be hardwired. A 5 year warranty is offered as an option. | 40 A, 9.6 kWabout 28.2 miles an hourSettings: 16 to 40 A | 50 A at top current | NEMA 14-50 plug, Hardwired | J1772, NACS | 25 ft | UL Type 4 | Yes | UL and cUL (E510712) | not stated | 3 years |
| Wallbox Pulsar Plus 40AWallboxMaker's page, read 2026-11-16 | 40 A, 9.6 kWabout 28.2 miles an hourSettings: 16 to 40 A | 50 A at top current | NEMA 14-50 plug, Hardwired | J1772, NACS | 25 ft | NEMA Type 4 | Yes | UL certification (NRTL), UL 2594 | Yes | 3 years |
Breaker sizes follow the 80 percent continuous-load rule. Miles an hour assume a car using 30 kWh per 100 miles and 12 percent charging loss; your car's onboard charger can cap it lower. Your electrician decides the circuit under your town's code.
How this table is kept
- Every maker value was read from the maker's own page or datasheet on the date shown, and the row links that page.
- A value the maker does not state reads not stated. Nothing is filled in from a retailer or a review.
- No prices. They change daily; the maker's page has today's.
- Being listed is not being recommended, and no maker pays to be listed. The short shelf is where the picks are.
Every link on this site is a plain link to the maker's own store. The site earns nothing from them today; if that changes, this note will name the program on every page. No maker pays for placement. How the shelf is picked.
The same table as data
Version 1.0.0, CC BY 4.0. Cite it, load it, or watch it for changes.